Quote Originally Posted by seckerich View Post
2. Do you now have voltage to the injectors at the plug? Do not expect a full 12 volt. Hook an ohm meter to the other wire and see if it cycles to ground when you spin the CAS. This will tell you if the computer is doing its job. Now you can be certain where the problem is. Common power wire in injector plug is black/yellow stripe, and signal wires (ground switching) are light green with stripes in the color for that location.
Clarification - this ohmeter test needs to be one of the primary injector plugs. The secondaries aren't used until after 3800 RPM.